<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-13 05-01-46
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 52 dBuV SANDELS
Pilot RDS Phase Difference
6.1 kHz 5.2 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
13 kHz 72 kHz 13346 12,0935
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,1 dBr 5,57 dBr 6,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 72 kHz MIN: 13 kHz % above 76 kHz: 12,0935 Acquired: 2025/07/13 5.00.42 Total samples: 13346 Equivalent time: 0:11:07 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 6,4 dBr MIN: 4,1 dBr AVE: 5,57 dBr % above 12,2 dBr: 0,0 Last value: 6,1 dBr (2025/07/13 5.00.41) 04.46 04.48 04.50 04.52 04.54 04.56 04.58 05.00 0 2 4 6 Pm [dBr]